  1. yes, after i became this unit, i did the last update from pioneer (for the newer versions). and i'm from germany.... i've a legal 3.0x Version ...so only 1 license... i have a backup with the diskrw-tool on wince before this update and also a backup from the whole "my flash disk" after this update. but i haven't got a backup of both wince-versions and also no backup from the sdmlc-drive...
  2. i cant update the newest update from pioneer. i've tried it to start from sd-card and also by clicking on update.exe in wince-mode. nothing happens then...
  3. i've found the license "Pioneer_PNA_FEU7PPC@0810_(EUMRE,_LM,_TMC)_2008-12-18_NN747.lic" on my backup...
  4. i need the full image for the avic f500bt eu-modell. i also need help restoring the Master Boot Record (MBR)...
  5. i know that testmode dont update wince...maybe my english isnt very good...and i have read thousands of posts here to solve my problem... the problem began, as i copied some files from a theme to the flashdisk in testmode. the wince says something about "could not write error" ... when i now start with the black screen, all of my backup data, that i've copied before with testmode on the flashdisk, was erased by the system...there are only some dump folders inside the flash... i also need help restoring the Master Boot Record (MBR)...i think, thats why the system don't boot up...
  6. i've found an older wince update here in the forum and installed it. then i came in the testmode. in testmode there are only folders with "dump..." on the flash disk. I deleted everything on the flash disk, copied my backup on the flash, turn the unit off, update the wince with the version of the newest update from pioneer. but when i then start the unit, again the black screen comes up. no startlogo, no start in the pioneer soft... so i need to update the older wince sw to go to the testmode....but what must i do then? nothing seems to work? my backup is already a 3.x Version (my unit
  7. okay, now i've access to the testmode...and i have copy my backup files to the system. But the systems doesnt starts...same as before...
  8. ...i think, that the mbr is dead...because the system doesnt start with the pioneer logo... first the blue light blinks, then it comes a black screen and after that it flashes white and then go out... can nobody help me???
  9. Hi there. Nothing works no more. The device just powers on with a 1/10 second white flashing screen after pressing power for about 10 seconds. With or without SD Card. No logo no way to start testmode. I believe the flash has been written wrong one time. The only chance i see is to update uboot.bin uboot.cks. Iread this step in another documentation. Can anybody provide me that files? I did not find anything regarding that device till now.
  10. ...when i have a testmode on the sd-card, the system starts, on screens the startpage (pioneer navgate), then the lights go on and then it shuts down...i have a european version...
  11. Hi, i've changed some files in the avic. Now it don't start the normal way. The screens hangs on the startpage (Pioneer navgate). Testmode didn't work. What can i do, to come in the testmode???
×
×